Construction work grade (Circular 34/2026/TT-BXD)

Choose the structure type and enter its size. The tool checks each criterion of Annex II Table 2, takes the highest grade, then compares it with the Annex I grade (if the work is listed in Annex I).

Updated Technical review: KS. Dương Văn TiếnFree, no sign-up
Quick answer

The work is Grade II (Buildings and building-type structures).

Inputs

m
m²
m
m

Leave a field at 0 to skip that criterion. The Annex I grade depends on the type of work and its capacity (e.g. schools by pupils, hospitals by beds, plants by output) in Tables 1.1–1.5 of Circular 34/2026.

Enter your data, then press Calculate (or Enter).

Preliminary results

Work gradeGrade II
By structure (Annex II)Grade II
By importance (Annex I)—
StepResultBasis
Height22 mGrade IIIAnnex II Table 2 item 2.1
Storeys above ground6Grade IIIAnnex II Table 2 item 2.1
Total floor area12,000 m²Grade IIAnnex II Table 2 item 2.1
Largest structural span30 mGrade IIIAnnex II Table 2 item 2.1
Basement levels1Grade IIIAnnex II Table 2 item 2.1
Underground depth4 mGrade IIIAnnex II Table 2 item 2.1
Work gradeHigher of Annex I and Annex IIGrade IIArticle 2(2), Circular 34/2026
Sources and assumptions. Circular 34/2026/TT-BXD of 25/06/2026 by the Ministry of Construction, effective 01/07/2026, replacing Circular 06/2021/TT-BXD (amended by 02/2025/TT-BXD). The tool covers 5 common structure types of Annex II Table 2; bridges, tunnels, dams, pipelines, ports and Annex I are not included. Ranges "a ÷ b" are taken as inclusive where the text is silent ⚠. Check the official text before filing. ⚠ = code table value to be checked against the original standard. Preliminary results for material selection and budgeting; not a substitute for an approved fire protection design.

Annex II Table 2 thresholds: Buildings and building-type structures

CriterionSpecial gradeGrade IGrade IIGrade IIIGrade IV
Height (m)> H*> 75 ÷ H*> 28 ÷ 75> 6 ÷ 28≤ 6
Storeys above ground> 5025 ÷ 508 ÷ 242 ÷ 71
Total floor area (m²)—> 30 000> 10 000 ÷ 30 0001 000 ÷ 10 000< 1 000
Largest structural span (m)> 200100 ÷ 20050 ÷ < 10015 ÷ < 50< 15
Basement levels—≥ 52 ÷ 41—
Underground depth (m)—> 186 ÷ 18< 6—

H* = 150 m for buildings of groups F1.2, F1.3, F4.2, F4.3 and mixed-use buildings (QCVN 06:2022/BXD 1.1.3); 200 m for other buildings. Floor area in m². Highlighted cells are the criteria your work meets.

What the grade is used for

  • Deciding which authority appraises the feasibility study and design and issues the building permit; a project with several main works takes the highest grade (Article 3).
  • Setting the capability requirements for survey, design, construction and supervision firms and individuals.
  • Quality management, acceptance, warranty and maintenance of each work; linear projects are graded work by work.
  • Projects approved, or validly submitted for appraisal, before 01/07/2026 keep the grade under the previous rules (Article 5).

Frequently asked questions

A one-storey factory 12 m high with a 60 m span: which grade?

Height 12 m and one storey give grades III and IV, but a 60 m span falls in 50 to under 100 m, so the work is grade II.

A 20-storey apartment block with 2 basements?

8–24 storeys is grade II and 2 basements is also grade II; if the total floor area exceeds 30,000 m² it becomes grade I.

How do Annex I and Annex II differ?

Annex I grades by importance and capacity for each type of work (civil, industrial, infrastructure, transport, agriculture). Annex II grades by structural size. If a work is in both, the higher grade applies.

Is the grade relevant to fire safety?

Yes. Together with use, height and volume, the grade drives the fire safety design appraisal file and the fire-resistance of the structure. See the Fire safety advisor tool to check whether appraisal is required.

Applicable documents

Documents in force at the update date, applied from 1 July 2026. TCVN standards are mandatory only when a QCVN refers to them; where they differ, the QCVN prevails.

CodeTitleEffective fromStatus
TT 34/2026/TT-BXDCấp công trình xây dựng01/07/2026In force
QCVN 06:2022/BXD + SĐ1:2023An toàn cháy cho nhà và công trình16/01/2023In force ⚠